note: "Markdown rendering of the canonical HTML page, generated at build for AI assistants and text tools. Figures and interactive elements are described, not reproduced. On Design Guide rules the source quote, this site's paraphrase and this site's editorial note are labelled separately and must not be conflated."
licence: "Datasets CC BY 4.0, census snapshot CC BY-NC 4.0 (https://cyclotroninfo.com/data/); cite as Cyclotron Info, cyclotroninfo.com"
---
# Coil Geometry Calculator

Before ordering wire, it pays to know what a winding actually becomes: how far it builds out radially, how many meters of conductor it swallows, what it weighs, and what resistance the power supply will see hot. This calculator models a conventional layer-wound solenoid coil. A cyclotron magnet uses two such coils, one per pole — the results below are for **one** coil.

*Interactive controls on the page (not operable here), with their defaults:*
- Coil inner diameter (mm) 300 mm ≈ 11.8 in: default 300
- Total turns N: default 500
- Conductor shape (choices: Square; Round): default Square
- Bare conductor size (mm) Side length (square) or diameter (round): default 2
- Insulation thickness per side (mm) Heavy-build magnet wire ≈ 0.04–0.1 mm; add any interlayer wrap here: default 0.1
- Layers: default 10
- Operating temperature (°C): default 80

[Figure, drawn on the page: Half cross-section of one layer-wound coil: the winding window as a grid of conductor cross-sections, with coil axis, inner and outer radius, and axial height dimensioned]

*Figure caption:* Half cross-section through one coil (axisymmetric about the dash-dot axis; the bore is broken — its width is not to scale). Each cell is one conductor at the winding pitch, in layers (radial) × turns per layer (axial). Window and conductor grid drawn to scale. Dimensions update with the inputs.

## Results

This calculator requires JavaScript; the formulas it uses are given in full below.

|   |   |
| --- | --- |
| Winding pitch (insulated size) | — |
| Turns per layer | — |
| Coil outer diameter | — |
| Coil axial height | — |
| Conductor length | — |
| Resistance at 20 °C | — |
| Resistance at operating temperature | — |
| Copper mass | — |

## The math

The winding pitch is the bare size plus insulation on both sides: s = s<sub>bare</sub> + 2t<sub>ins</sub>. With N turns in n<sub>L</sub> layers, each layer carries ⌈N/n<sub>L</sub>⌉ turns; layer k (counting from 0) winds at mean diameter

D<sub>k</sub> = D<sub>inner</sub> + (2k + 1)·s

Conductor length is the layer-by-layer sum ℓ = Σ (turns in layer k) · πD<sub>k</sub>, the outer diameter is D<sub>inner</sub> + 2n<sub>L</sub>s, and the axial height is (turns per layer) · s. Resistance and mass follow from the bare copper cross-section A (side² for square, πd²/4 for round):

R = ρℓ/A, ρ(T) = ρ₂₀ [1 + α(T − 20 °C)], m = δAℓ

with annealed-copper values ρ₂₀ = 1.724 × 10⁻⁸ Ω·m (100% IACS), α = 0.00393 K⁻¹, δ = 8960 kg/m³. Magnet coils run warm: expect roughly +24% resistance at 80 °C over the nameplate 20 °C value, and size the power supply for the hot resistance.

### Assumptions and limits

- Ideal square-packed winding: every turn lands at exactly one pitch. Real coils wind slightly proud — add a few percent to the radial build, more for round wire wound loose.
- Round-wire orthocyclic (hexagonal) packing, bobbin flanges, leads, and interlayer cooling plates are not modeled.
- Length uses the mean diameter of each layer; helical pitch adds a negligible √(1 + (s/πD)²) correction for any sane geometry.

### Worked check

300 mm ID, 500 turns of 2 mm square wire with 0.1 mm insulation per side (pitch 2.2 mm) in 10 layers: 50 turns/layer, OD = 344 mm, height = 110 mm, ℓ = 506 m, R₂₀ = 2.18 Ω, R₈₀ = 2.69 Ω, mass = 18.1 kg. (Cross-check the mass: 4 mm² × 506 m × 8960 kg/m³ = 18.1 kg.)

### Sources

- Copper properties: International Annealed Copper Standard (IACS); CRC *Handbook of Chemistry and Physics*, resistivity of metals.
- Winding geometry: standard practice, e.g. D. B. Montgomery, *Solenoid Magnet Design*, Wiley-Interscience, 1969, ch. 1.

The [magnet design](https://cyclotroninfo.com/learn/magnet-design/) page covers how coil geometry trades against the rest of the magnet.

Educational reference, not an operating procedure: results reflect the stated model and assumptions. Verify anything safety-critical against primary sources, and read the [safety fundamentals](https://cyclotroninfo.com/learn/safety/) before applying numbers to real hardware. Last reviewed: 11 August 2026 · [Report a correction](mailto:info@cyclotroninfo.com?subject=Correction%3A%20Coil%20Geometry%20Calculator).